As a backup of previous posts and because of a special relationship to this product.
Features
Wakeup from OFF:
RC voltage rising to >=5V: UG appears as a “battery” of ~5V with low inner resistance for 5s
then: “battery” off, UG measures the RC voltage and remembers it
Runtime:
UG acting as voltage spatula. In practise: stepping in several times a second.
BEC power failure: UG takes over at remembered voltage minus 0.5V *)
Auto-Poweroff (no RC voltage) or by Button
Hibernation mode
Remaining leakage current: Disconnect LiPo when UG is not in use for >2 months
Power Source: 2S LiPo
Auto-Charging
Balancing
Lower impedance than the LiPo itself: buck-boost regulator
5A continuous, 10A intermittent
Options:
super-bright signal LED for alarming (3* white), cascadable
Opti Button: remote on/off
*) Purpose of <remembered minus 0.5V> step-in voltage: In order to allow to set a voltage alarm threshold by common means of any telemetry system.
.
How UG as a “battery” at power-up cures: SPEKTRUM satellite receivers on Vbar FBL: before, after (On a Sunday in Feb 2015: user (Malcolm) reported an issue in HF, – R2 modified the UG firmware for acting as “battery” at startup. Standard in all UG delivered May 2015 and later.)